The LT9000 level transmitter provides continuous measurement of electrically conductive liquids that do not leave a sticky residue or buildup. Ideal solution for short measuring ranges or tanks and vessels containing obstructions that would normally interfere with non-contact type sensors. Measurement is unaffected by changes in pressure, temperature or media density. No moving parts eliminates break downs, providing maintenance free operations.
Overview
The LT9000 level transmitter utilizes Radio Frequency admittance technology, which measures the change in capacitance between the sensor probe and the vessel wall in order to determine the level. Any change in level causes a capacitance change, which is converted into a 4/20mA output signal. This signal can then be sent to a local display, PLC or other programable controller.
The standard unit is made of a solid stainless-steel probe fully insulated with a non-conductive coating such as HALAR or thick TEFLON SLEEVE – both compatible with a wide variety of aggressive liquids. Inside the explosion proof housing are the sensing electronics and manual calibration adjustment. The isolated 4-20 mA output signal can drive a load of up to 1000 ohms. The zero and span can be set over the entire length of the probe or any portion of the probe. The entire unit is backed by a two-year warranty, 60-day money back guarantee.
For ordering information, refer to ordering information below. Not sure what model is right for your application, fill out the data application PDF.
LT9000 Level Transmitter
Features
- 4-20mA output
- Fully isolated output
- No moving parts
- Simple installation and calibration
- Explosion proof housing standard
- On board fuse protection
- Modular electronics easily replaced
- Temperature stable electronics
Applications
- Continuous level transmission of non-coating, conductive fluids
Liquids:
- Water
- Acids
- Wastewater
Specifications
ELECTRICAL:
Power: 115VAC (+/- 15%) 50/60Hz or 24VDC
Output: 4-20mA into a load of 1K ohm max.
On Board Fuse: .5A @ 125 volts
Frequency: 10,000Hz to 300,000Hz
ENVIRONMENTAL:
Temperature: Probe: -30F to 340F - HALAR
-30F to 250F – TEFLON SLEEVE
Pressure: 1500 psi @ 75F – 1” NPT STANDARD
300 psi @ 75 F – ¾” NPT (Optional)
Enclosure: Cast Aluminum, Explosion Proof - Class I, Groups C & D; Class II, Groups E, F & G